- New RF80-K PC
Interface with ABMS-8
Battery Management System
- Simple, Straight-Forward Operation
- Heavy Duty Design and Performance
- Digital Timers & Displays
- Charges and Analyzes All Aircraft Batteries
- Ni-Cd and Lead-Acid, all manufacturers
- Unique ReFLEX Quick-Charger
- Constant Current Charge
- 2-Step Constant Current Charge
- Constant Potential Charge, for Lead Acid
- Constant Current Discharge, for Capacity Testing
- DigiFLEX Analysis for Visual Status Indication
- Cell Voltage Balance Testing, Internal Voltmeter
- CE European Approval, RF80-K (CE)
Note: The RF80-K model replaces the previous RF80H design, which was discontinued in 1991.
Size:
18.5" (47.1 cm) wide × 21.5"
(54.6cm) deep × 11" (27.9 cm) high
Cabinet:
17"(43.2cm) wide × 20.8" (52.3cm) deep × 1.25"(26cm) high
Net weight:
145 pounds (65.9 kg)
Front Panel Material:
Steel with polyester overlay
Case material:
Steel
Voltage:
110, 208, 220 VAC
Frequency:
50/60 Hz
Current:
25 amperes, maximum
| |
Unique RF80-K ReFLEX Charge:
2 to 80A
Constant Current Charge:
1 to 65A, maximum
Constant Current Discharge:
0.2 to 50A
Current:
99.9 full scale, accuracy ±2% of full scale
Individual Cell:
19.9 full scale, accuracy ±2% of full scale
DigiFLEX:
10 segment trend bar display
Ambient Temperature:
-40°C to +71°C
Altitude:
0 to 50,000 feet
Ambient temperature:
0 °C to 50 °C
Altitude
0 to 8,000 feet

Two year parts and labor
|